testo SaverisTM measuring system with GSM module integrated

  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
  • testo SaverisTM measuring system with GSM module integrated
TESTO AG
Тesto Saveris monitoring system for measurement data compliant with EN 12830; measures temperature and humidity values. Incl. testo Saveris Base (GSM module integrated, radio frequency 868 MHz), radio probes, Ethernet probes, Software, Router, Converter
 
Part #: 0572 0221

Description

The new testo Saveris measurement system measures temperature and humidity values in the environment and in processes.The easy-to-use measurement system delivers safety and time savings thanks to automated measurement data recording.
testo Saveris is ideal for
· the monitoring and documentation of temperature or humidity data in production, quality assurance and R&D as well as in buildings
· monitoring of the storage climate of temperature and humidity-sensitive products, such as valuable inventory (museums, server rooms), of medicines and of foodstuffs
· and monitoring of the foodstuff cooling chain.
The testo Saveris radio probes measure temperature and humidity. In the measuring cycle, the probes save their measurement data and send it to the central base at regular intervals. If a limit value is exceeded, a radio link is established immediately. Through bidirectional transmission, the radio probe and the base are in mutual contact. This therefore ensures that the measurement data is only recorded by the base and is not interfered with by other radio systems.
An alarm sounds in the event that the radio link is interrupted by obstacles. The memory in the probe ensures that the measurement data is not lost in the event of an interference in the radio link.
In free field, the transmission path is approx. 300 m at a frequency of 868 MHz and approx. 100 m at a frequency of 2.4 GHz. In buildings, the transmission path is strongly influenced by structural conditions such as walls, refrigerator doors or metal doors. The radio link can be improved or lengthened with poor structural conditions by using a router.Probe versions with internal and external sensors allow the adaptation to every aplications. The radio probes are available with or without a display as an option. Current measurement data, the battery status and the quality of the radio link are shown on the display.
In addition to the radio probes, probes can be used that are directly connected to the Ethernet. The existing LAN infrastructure can be used through this. This allows the data transfer from the probe to the base, even over long distances. Ethernet probes can be used over any long periods since they are connected to the mains and therefore work independently of batteries. The internal memory guarantees that the existing measurement data is not lost, even with failure of the mains or the LAN connection. A display informs about the current measurement data as well as the probe status. Through the connection of a converter to an Ethernet jack, the signal of a radio probe can be converted into an Ethernet signal.
The base is the heart of testo Saveris and can save 40,000 readings. An emergency battery ensures that an alarm is transmitted and that no existing data is lost in the event of a power failure.
The system data and alarms are visible via the display of the Saveris base. Even without the PC running, the base issues an alarm by means of an LED if the limit value is exceeded, or optionally via SMS.
In total, a base can incorporate 150 radio and Ethernet probes or 450 measurement channels. The Saveris base is connected to the PC either via USB or Ethernet cable. The Saveris base thereby offers flexibility with the highest data security.
The measurement data is transmitted from the base to a PC on which the testo Saveris software is installed. All measurement data is saved centrally in the software's database and can be called up any time as a table or a graphic. All alarms that occur are listed in a table as a history.
The automatic creation of PDF reports in defined intervals also simplifies the documentation. Using the calendar function and the consolidation of probes into groups, the operation of the software is simple and intuitive. In the event of an alarm the user can choose between receiving a message via e-mail or a pop-up directly on the screen.
Advantages of testo Saveris:
  • time saving due to automated measuring data acquisition
  • unique flexibility due to the combination of radio probes and Ethernet probes
  • easy installation, configuration and operation
  • high data security due to multi-level storage concept
  • continuous documentation of the measurement data
  • alarm if limit values exceeded (also with switched-off PC)
  • flexibility due to various probe versions
  • large internal store
  • Energy supply via mains, additional emergency battery for data security
  • Saveris converter, 868 MHz

    # 0572 0118

    Сonverts the radio transmission medium to Ethernet

  • Saveris Extender

    # 0572 0217

    Сonverts the radio transmission medium to Ethernet, radio frequency 868 MHz, for Saveris Base

  • Saveris Converter V2.0

    # 0572 0218

    Сonverts the radio transmission medium to Ethernet, radio frequency 868 MHz, for all Saveris Base Firmware versions, for wireless probes with Firmware Version V 2.X

  • Saveris Router V2.0

    # 0572 0219

    Saveris Router V2.0, radio transmission medium, radio frequency 868 MHz, for Saveris Base Firmware Version V 2.X

  • Saveris Cockpit Unit

    # 0572 0222

    Saveris Cockpit Unit, Display for showing alarms and system data, Printout of readings using infrared printer, Up to 8 probes can be connected, Wireless, USB and infrared interfaces, radio frequency 868 MHz

  • Penetration probe NTC with ribbon cable

    # 0572 1001

    Сable length 2 m, IP 54 Meas. range -40 to +125 °C, ±0,2 °C (-25 to +80 °C)

  • Saveris T1E Ethernet probe

    # 0572 1191

    with 1 external probe connection NTC

  • Saveris T1 - radio probe with internal NTC

    # 0572 1210

    Without display, radio frequency 868 MHz Meas. range -35 to +50 °C The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X.

  • Saveris T2 - radio probe

    # 0572 1211

    With external probe connection and internal NTC. Without display, radio frequency 868 MHz Meas. range -35 to +50 °C -50 to +150 °C The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X

  • Saveris T1 D - radio probe with internal NTC

    # 0572 1220

    With display, radio frequency 868 MHz Meas. range -35 to +50 °C The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X

  • Saveris T2 D - radio probe

    # 0572 1221

    With external probe connection and internal NTC. With display, radio frequency 868 MHz Meas. rangе: - intern. sensor -35 to +50 °C -extern. sensor -50 to +150 °C Тhe Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X

  • Saveris U1E Etheret analog coupler

    # 0572 3190

    with 1 curent/voltage input.

  • Saveris U1 Analog coupler

    # 0572 3210

    with 1 current/voltage input. The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X

  • Humidity / Temperature Probe 12mm, L=1.3 m

    # 0572 6172
    Meas. range -20 to +70 °C, 0 to +100 %RH
    Accuracy   ±0,3 °C / ±2 %RH at +25 °C (2 to 98 %RH) / ±0,03 %RH/K
  • Humidity / Temperature Probe 4 mm, L= 2,2 m

    # 0572 6174
    Meas. range 0 to +40 °C, 0 to +100 %RH
    Accuracy ±0,3 °C / ±2 %RH at +25 °C (2 to 98 %RH)    ±0,08 %RH/K ± 1 digit
  • Saveris H1 E - Humidity Ethernet probe 1%

    # 0572 6191

    With display. Meas. range: - Humidity sensor 0 to 100 %RH - NTC -20 to +70 °C

    Accuracy ±0.2 °C (0 to +30 °C) 
                     0.5 °C Remaining Range

                ±1 %RH (< 90 %RH) +0.7 % of mv at +25 °C
               ±1.4 %RH (> 90 %RH) +0.7 % of mv at +25 °C
               0.0 %RH/K

     

    Resolution  0.1 °C

  • Saveris H2 E - Humidity Ethernet probe 2 %

    # 0572 6192

    With display. Meas. range: - Humidity sensor 0 to 100 %RH - NTC -20 to +70 °C

  • Saveris H4E Ethernet humidity probe

    # 0572 6194

    with external probe connection (with display).

  • Saveris H3 - humidity radio probe

    # 0572 6210

    Internal NTC, without display, radio frequency 868 MHz Meas. range: - NTC -20 to +50 °C -Humidity sensor 0 to 100 %RH The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X

  • Saveris H3 D Humidity recorder internal 3 % RH

    # 0572 6220

    With display, radio frequency 868 MHz. The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X

  • Saveris H2D Wireless probe with external humidity sensor 2%RH

    # 0572 6222

    Radio frequency 868 MHz. The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X.

  • Saveris H4D Wireless humidity probe with external probe connection

    # 0572 6224

    Radio frequency 868 MHz. The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X

  • Penetration probe Pt100 with ribbon cable

    # 0572 7001
    Temperature - Pt100
    Technical data
     
    Measuring range
    -85 to +150 °C
    Accuracy
    Class A
    Reaction time
    35 s
     
    General technical data
    Technical data
     
    Length probe shaft
    60 mm
    Protection class
    IP54
    Fixed cable
    yes
    Cable length
    2 m
    Diameter probe shaft tip
    3.6 mm
    Diameter probe shaft
    5 mm
    Length probe shaft tip
    30 mm
  • Saveris Pt E - Ethernet probe

    # 0572 7191

    With external Pt100 probe connection. With display. Meas. range -200 to +600 °C

  • Saveris Pt- radio probe

    # 0572 7211

    With 1 external Pt100 probe connection. Without display, radio frequency 868 MHz Meas. range -200 to +600 °C The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X

  • Saveris Pt DTemperature recorder external Pt100

    # 0572 7221

    With display, radio frequency 868 MHz The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X

  • Penetration probe TC with ribbon cable

    # 0572 9001

    Type K, cable length 2 m, IP 54 Meas. Range -40 to + 220 °C

  • Saveris T4 E, 4-channel Ethernet probe

    # 0572 9194

    With 4 external TC probe connections. With display. Meas. range: type T -200 to +400 °C type S 0 to +1760 °C type K -195 to +1350 °C type J -100 to +750 °C

  • Saveris T3, 2-channel radio probe

    # 0572 9212

    With 2 external TC probe connections. Without display, radio frequency 868 MHz Meas. range: - type K -195 to +1350 °C - type J -100 to +750 °C - type T -200 to +400 °C - type S 0 to +1760 °C The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X

  • Saveris T3 D, 2- channel radio probe

    # 0572 9222

    With 2 external TC probe connections. With display, radio frequency 868 MHz: Meas. range: - type K -195 to +1350 °C - type J -100 to +750 °C - type T -200 to +400 °C - type S 0 to +1760 °C The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X

  • Thermocouple with TC adapter

    # 0602 0644

    Flexible, 800mm long, fibre glass, TC Type K (usable with handle part no. 0409 1092) Meas. Range -50 to +400 °C

  • Robust air probe, T/C Type K

    # 0602 1793
    Meas. Range -60 to +400 °C, 
  • Pipe wrap probe

    # 0602 4592

    For pipe diameter 5 to 65 mm, with exchangeable measuring head. Meas. range short-term to +280°C, TC Type K Meas. Range -60 to +130 °C

  • Magnetic probe

    # 0602 4792

    Аdhesive force approx. 20 N, with magnets, for measurements on metal surfaces, TC Type K Meas. Range -50 to +170 °C

  • Magnetic probe

    # 0602 4892

    Аdhesive force approx. 10 N, with magnets, for higher temp., for measurements on metal surfaces, TC Type K Meas. Range -50 to +400 °C

  • Immersion measurement tip, flexible

    # 0602 5693

    For measurements in air/exhaust gases (not suitable for measurements in smelters), TC Type K Meas. range -200 to +1300 °C

  • Immersion tip, flexible

    # 0602 5792

    TC Type K Meas. Range -200 to +1000 °C

  • Robust, waterproof Pt100 immersion/penetration probe

    # 0609 1273

    Meas. range -50 to +400 °C

  • Robust, Pt100 stainless steel food probe (IP65)

    # 0609 2272

    Meas. range -50 to +400 °C

  • Waterproof NTC immersion/penetration probe

    # 0613 1212

    Meas. range -50 to +150 °C, Accuracy ±0.2 °C (-25 to +74.9 °C), Reaction time 10 s

  • Stainless steel NTC food probe (IP65) with PUR cable

    # 0613 2211
    Meas. range  -50 to +150 °C
    Accuracy      ±0.2 °C (-25 to +74.9 °C)
                        ±0.4 °C (Remaining Range)
    Reaction time   8 s
    fixed cable 1.6 m
  • Pipe wrap probe with Velcro

    # 0613 4611

    For pipe diameter to max. 75 mm, Tmax. +75°C, NTC Meas. range -50 to +70 °C

  • Accurate immersion/penetration probe

    # 0628 0006

    Сable: 1.5 m long, IP 67 Meas. range -35 to +80 °C

  • Pipe wrap probe with Velcro strip

    # 0628 0020

    For temperature measurement on pipes with diameter up to max. 120 mm, Tmax +120°C, TC Type K Meas. Range -50 to +120 °C

  • Stationary probe with aluminium sleeve

    # 0628 7503

    IP 65 Meas. range -30 to +90 °C

  • Wall surface temperature probe

    # 0628 7507

    Тo prove damage in building material Meas. range -50 to +80 °C

  • Stub probe, IP 54

    # 0628 7510

    Meas. range -20 to +70 °C

  • Stationary probe with stainless steel sleeve

    # 0628 7533

    TC Type K Meas. Range -50 to +205 °C

  • Progamming adapter

    # 0440 6723

    (from mini-DIN to USB) for Ethernet probe and converter (necessary if no DHCP server available)

  • Connection cable

    # 0554 0213

    For Pt100 stationary probe with screw terminals (4-wire technology)

  • Magnetic foot aerial, with 3m cable

    # 0554 0524
  • Testo fast printer

    # 0554 0549

    With wireless infrared interface, 1 roll thermal paper and 4 AA batteries (for printing out measurements on site)

  • Saveris protective housing

    # 0572 0200

    For protection from high-pressure cleaning and impact, IP 69 K suitable for wireless probes T1 /T1D / T2 / T2D

  • Alarm module (visual + acoustic), can be connected to base alarm relay

    # 0572 9999

    (Ø 70 x 164 mm, 24 V AC/DC / 320 mA, perm. light: red, perm. tone: buzzer approx. 2.4 kHz (Mains unit 0554 1749 required))

  • ISO cal. cert./humidity

    # 0520 0076

    (humidity data logger; calibration points 11.3%RH and 75.3%RH at +25°C)

  • ISO calibration certificate/temperature

    ISO calibration certificate/temperature

    # 0520 0151
    (temp. data logger; calibration points -18°C; 0°C; +60°C)
  • ISO calibration certificate/ air temperature

    ISO calibration certificate/ air temperature

    # 0520 0171
    Calibration points -8°C, 0°C, +40°C
  • DAKKS calibration cert./humidity

    # 0520 0246

    (humidity data logger; cal. points 11.3%RH and 75.3%RH at +25°C)

  • DAKKS calibration certificate/temperature

    DAKKS calibration certificate/temperature

    # 0520 0261
    (temp. data logger; cal. points -20°C; 0°C; +60°C)
Memory                                                                         40,000 values per channel (total max. 10,160,000 values)
Dimensions                                                                    225 x 150 x 49 mm
Weight                                                                            Approx. 1510 g
Protection class                                                              IP42
Material/Housing                                                           Diecast zinc / plastic
Radio frequency                                                             868 MHz / 2.4 GHz
Power supply (absolutely necessary)                            6.3 V DC mains unit; alternatively via 24 V AC/DC plug- in/screw terminals, power consumption < 4 W
Rech. batt.                                                                      Li-ion battery (for data back-up and for emergency SMS with failure of the power supply)
Oper. temp.                                                                   -10 to +50 °C
Storage temp.                                                                -40 to +85 °C
Display                                                                           graphical display, 4 control keys
Interfaces                                                                       USB, radio, Ethernet
Connectable radio probe                                               max. 15 probes can be directly connected via radio interface, max. 150 total via radio/router/converter/Ethernet, max. 450 channels
Alarm relay                                                                    max. 1 A, max. 30 W, max. 60/25 V DC/AC, NC or NO contact
GSM module                                                                 850/900/1800/1900 MHz not valid for Japan and South Korea
Set up                                                                             Table base and wall bracket included
 
  • Saveris Set 1 - 868 MHz

    Saveris Set 1 - 868 MHz

    # 0572 0210
    Set: 868 MHz, consisting of base 0572 0220, 3 NTC radio probes without display 0572 1210, mains unit for base 0554 1096 and SBE software 0572 0180 incl. USB cable.
 

Enquiry Form

Related products

  • testo 175 T2

    testo 175 T2

    2-channel temperature data logger with internal (NTC) and external sensor connection (NTC)
  • testo 184 T4 - temperature data loggers

    testo 184 T4 - temperature data...

    testo 184 T4 - temperature data logger, especially designed for transport applications, multi-use logger for dry ice applications (-80 °C),...
  • testo 175 T3

    testo 175 T3

    2-channel temperature data logger with external sensor connections (TC Type T and Type K)