testo 521-2

  • testo 521-2
  • testo 521-2
  • testo 521-2
  • testo 521-2
TESTO AG
testo 521-2, differential pressure meter 0...100 hPa / +-0.1 % fsv., incl. battery and manual
 
Part #: 0560 5211

Description

  • The high-precision testo 521-2 differential pressure measuring instrument is ideal for accurate differential pressure measurements in air conditioning and ventilation technology, for instance for pressure drop on filters, checking fans and extractors or for Pitot tube measurements.

    Product benefits:

  • Integrated differential pressure sensor with an accuracy of 0.1 % of f.v.
  • Calculation of the flow velocity and the volume flow via Pitot tube (optional)
  • Multi-point and timed mean calculation
  • 2 probe inputs for additional pressure and temperature probes
     

PC Software

  • Current/voltage cable

    # 0554 0007

    (±1 V, ±10 V, 20 mA) Meas. Range 0 to +1000 mV, 0 to +10 V , 0 to +20 mA

  • 4 to 20 mA interface

    # 0554 0528

    4 to 20 mA interface for connection and intermittent power supply to transmitters (scaling via hand-held instrument), in robust metal housing with impact protection, incl. magnet for fast attachment

  • Pipe wrap probe Type K (NiCr-Ni)

    # 0600 4593

    For pipes with diameter of up to 2", for flow/return temp. meas. in hydronic systems Meas. Range -60 to +130 °C

  • Super quick-action immersion/penetration probe Type K (NiCr-Ni)

    # 0604 0493

    For measurements in liquids (Plug-in head, connection cable 0430 0143 or 0430 0145 required) Meas. Range -200 to +600 °C

  • Highly accurate air probe

    # 0610 9714

    for air and gas temperature measurements with bare, mechanically protected sensor Measuring range -40 to +130 °C

  • Pitot tube, 500 mm long, Ø 7 mm

    # 0635 2045

    Stainless steel, measures flow speed (Longer versions on request)

  • Pitot tube, 350 mm long, Ø 7 mm

    # 0635 2145

    Stainless steel, measures flow speed (In conjunction with 0638 1347 / 0638 1447 / 0638 1547 pressure probes or testo 521, with internal sensor)

  • Precision pressure probe, 100 Pa

    # 0638 1347

    It is in robust metal housing with impact protection, incl. magnet for fast attachment, to measure differential pressure and flow speeds (in combination with Pitot tube) Meas. Range 0 to +100 Pa

  • Pressure probe, 10 hPa

    # 0638 1447

    It is in robust metal housing with impact protection incl. magnet for fast attachment, to measure differential pressure and flow speeds (in combination with Pitot tube) Meas. Range 0 to +10 hPa

  • Pressure probe, 100 hPa

    # 0638 1547

    It is in robust metal housing with impact protection, incl. magnet for fast attachment, to measure differential pressure and flow speeds (in combination with Pitot tube) Meas. Range 0 to +100 hPa

  • Low pressure probe

    # 0638 1741

    Refrigerant-proof stainless steel (screw-in thread 7/16" UNF) Meas. Range -1 to +10 bar

  • High pressure probe

    # 0638 1841

    Refrigerant-proof stainless steel (screw-in thread 7/16" UNF) Meas. Range -1 to +30 bar

  • High pressure probe

    # 0638 1941

    Refrigerant-proof stainless steel (screw-in thread 7/16" UNF) Meas. Range -1 to +40 bar

  • High pressure probe

    # 0638 2041

    Refrigerant-proof stainless steel (Screw-in thread 7/16" UNF) Meas. Range -1 to +100 bar

  • RS 232 cable

    # 0409 0178

    Сonnects instrument to PC (1.8 m) for data transfer)

  • Connection cable 2.5 m long

    # 0409 0202

    For pressure probes 0638 1741/1841/1941/2041/2141

  • Cable, 1.5 m long

    # 0430 0143

    Сonnects CO2 probe with plug-in head to meas. instrument (PUR coating material)

  • Cable, 5 m long

    # 0430 0145

    Сonnects probe with plug-in head to measuring instrument (PUR coating material)

  • 9V rech. battery for instrument

    # 0515 0025

    (instead of battery)

  • TopSafe (indestructible protection case)

    TopSafe (indestructible protection case)

    # 0516 0441
    Incl. bench stand and belt clip (IP 65, protects instrument from water, dust, impact, scratches, chemicals)
  • TopSafe (protection case)

    # 0516 0446

    Incl. carrier strap, bench stand and magnet. Protects instrument from dust, impact, scratches

  • System case

    System case

    # 0516 0526
    For measuring instrument, probes, straight or Prandtl Pitot tube, accessories
  • Transport case

    Transport case

    # 0516 0527
    for measuring instrument, probes, Prandtl Pitot tube, accessories
  • Connection hose, silicone, 5m long

    # 0554 0440

    (max. load 700 hPa (mbar))

  • Testo fast printer

    # 0554 0549

    With wireless infrared interface, 1 roll thermal paper and 4 AA batteries (for printing out measurements on site)

  • Spare thermal paper for printer (6 rolls

    # 0554 0568

    (measurement data documentation legible for up to 10 years)

  • Desk-top power supply with international connection options

    # 0554 1143
  • Ethernet adapter

    # 0554 1711

    Ethernet adapter, RS232 - Ethernet incl. software driver, mains unit (facilitates data communication in network)

  • Adapter for pressure probes, 1/2

    Adapter for pressure probes, 1/2" outer thread, 1/4" inner thread

    # 0699 3127
    (for pressure probes 0638 1741/1841/1941/2041/2141)
  • DAKKS calibration certificate/Pressure

    DAKKS calibration certificate/Pressure

    # 0520 0205
    (Differential pressure, accuracy < 0.1 (% of full scale value))
  •   ISO calibration certificate/Pressure

    ISO calibration certificate/Pressure

    # 0520 0035
    (Differential pressure, accuracy < 0.1 (% of full scale value))
  • ISO calibration certificate/temperature

    ISO calibration certificate/temperature

    # 0520 0001
    (for air/immersion probes, calibration points -18°C; 0°C; +60°C)
  • ISO calibration certificate/temperature

    ISO calibration certificate/temperature

    # 0520 0021
    (meas. instr. with air/immersion probe; cal. points 0°C; +150°C; +300°C)
  • ISO calibration certificate/pressure

    ISO calibration certificate/pressure

    # 0520 0025
    (differential pressure, accuracy 0.1 to 0.6 (% of fsv))
  • ISO calibration certificate/temperature

    ISO calibration certificate/temperature

    # 0520 0071
    (meas. instr. with surface probe; calibration points +60°C; +120°C; +180°C)
  • ISO calibration certificate/absolute pressure

    ISO calibration certificate/absolute pressure

    # 0520 0125
    5 measurement points distributed over meas. range (absolute pressure, accuracy 0.1 to 0.6 (% of fsv))
  • DAKKS calibration certificate/temperature

    DAKKS calibration certificate/temperature

    # 0520 0211
    (meas. instr. with air/immersion probe; calibration points -20°C; 0°C; +60°C)
  • DAKKS calibration certificate/pressure

    DAKKS calibration certificate/pressure

    # 0520 0212
    (absolute pressure; 11 measuring points distributed over meas. range)
  • DAKKS calibration certificate/pressure

    DAKKS calibration certificate/pressure

    # 0520 0215
    (diff. and pos. pressure; 11 measuring points distributed over the instr. meas. range)
  • DAKKS calibration certificate/pressure

    DAKKS calibration certificate/pressure

    # 0520 0225
    (diff. and pos. pressure; 6 meas. points distributed over meas. range (>0.6% of fsv))
  • DAKKS calibration certificate/temperature

    DAKKS calibration certificate/temperature

    # 0520 0271
    (contact surface temperature probes; calibration points +100°C; +200°C; +300°C)
  • ISO calibration certificate/Pressure

    ISO calibration certificate/Pressure

    # 0520 0405
    (Differential pressure, accuracy > 0.1 (% of fsv))
  • ISO calibration certificate/electrical

    ISO calibration certificate/electrical

    # 0520 1000
    (calibration in measurement ranges 0 to 20 mA; 4 to 20 mA; 0 to 1 V; 0 to 10 V)
  • ISO calibration certificate temperature

    # V400 0000
Memory
25.000
Storage temperature
-20 to +70 °C
Operating temperature                                      
0 to +50 °C
Power supply
Battery/Rechargeable battery,Mains unit 12 V
Battery type
9 V, IEC 6LR61
Weight
300 g
Dimensions
219 x 68 x 50 mm
Material/Housing
ABS
 
Probe type NTC
 
Meas. range                                                      
-40 to +150 °C
Accuracy
±0,2 °C (-10 to +50 °C)
±0,4 °C (remaining range)
Resolution
0.1 °C
 
Probe type Type K
 
Meas. Range
-200 to +1370 °C
Accuracy
±0,4 °C (-100 to +200 °C)
±1 °C (remaining range)
Resolution
0,1 °C
 
Probe type Piezoresistive pressure sensor
 
Meas. Range
0 to 100 hPa
Accuracy
±0.1 % of fsv
Resolution
0.01 hPa
Overload
300 hPa
 
Probe type Piezoresistive pressure sensor 2
 
Meas. Range
0 to 2000 hPa
Accuracy
±0.1 % of fsv
Resolution
0.1 Pa ( 06381347 )
0.001 hPa ( 06381447 )
0.01 hPa ( 06381547 )
0.1 hPa ( 06381847 )
 

Enquiry Form

Related products

  • testo 435-3

    testo 435-3

    testo 435-3, multi-functional measuring instrument with built-in differential pressure measurement for air conditioning, ventilation and Indoor Air Quality, with battery
  • testo 435-4

    testo 435-4

    testo 435-4, multi-functional meas. instr. with built-in differential pressure measurement for A/C, ventilation and Indoor Air Quality with readings memory,...
  • testo 435-2

    testo 435-2

    testo 435-2, measuring instrument for A/C, ventilation and Indoor Air Quality with memory, PC software, USB data transmission cable, incl....