TESTO AG
testo 350 Analysis Box, O2, incl. differential pressure sensor, type K NiCr-Ni and type S temperature sensor port, Pt10Rh-Pt, Testo data bus port, rechargeable battery, built-in combustion air sensor (NTC), trigger port, data memory, USB interface
 
Part #: 0632 3510

Description

Depending on the requirement, the testo 350 consists of a control unit, an analyzer box and a gas sampling probe. Using the removable control unit or in direct connection to a PC or laptop (USB or Bluetooth® 2.0), the analyzer box can be easily operated. The transfer of measurement data is therefore possible even when the exhaust gas flue and the adjustment site are spatially separated. After easy configuration of the measurement procedure by the user, the analyzer box carries out the measurements automatically and stores the measurement values. The measurement values are clearly presented in the large, colour graphic display of the control unit.
 
The Analysis Box comes standard equipped with an O2 gas sensor. You will, however, need to connect at least one more sensor (max. six) to operate the Box. Optional sensors include gas sensors for CO, CO2, NO, NO2, SO2, H2S and CxHy.
  • Innovative: The application-guided operation with helpful instrument pre-settings
  • Elegant and clear: The large colour graphic display
  • Robust design: The sealed housing makes the testo 350 insensitive to knocks and dirt
  • Cost and time-savings: The new service concept offers fast access to wearing parts
Aplications:
 
The portable flue gas analyzer testo 350 is the ideal tool for professional flue gas analysis. Helpful instrument settings guide the user safely through typical measurement tasks such as:
  • Flue gas analysis in commisioning, setting, optimization or operational measurements on industrial burners, stationary industrial engines, gas turbines and flue gas purification systems.
  • Control and monitoring of officially prescribed emission limits in exhaust gas.
  • Function testing of stationary emission measuring instruments.
  • Control and monitoring of defined gas atmospheres in furnace rooms or kilns in different processes.
Advantages:
  • Helpful instrument pre-settings save time
  • Unrestricted measurement at high concentrations
  • High availability even under difficult conditions
  • High measurement accuracy even in unsupervised measurements
  • Easy, precise test gas adjustment by the user
  • Use under tough conditions
  • Highly accurate NOx measurements at low concentrations
  • Automatic measurement range enxtension for unexpectedly high 
    CO concentrations
  • Excellently suited to long-term measurements
  • Simultaneous exhaust gas analysis at different measuremnt sites
 
 
ЕasyEmission:
  • Real-time monitoring window, allowing you to keep working with other programs and keep testing
  • Fast data transfer to Microsoft Excel or PDF
  • Easy-to-read, clear tabular, graphical, and picture box displays
  • Seamless calculations of maximum, minimum, and average values
  • Integrated report generation
  • User-defined reports and printouts
  • Customer and site location management functions for site management testing
  • Multi Analyzer viewing and control
Analyzer Control with easyEmission
  • Wireless-ready with fast real-time measurement via USB or optional Bluetooth
  • Supports connecting multiple emission analyzers together *
  • User-defined measuring intervals
  • Advanced settings for user defined fuel factor specification for custom fuels
Upgrade-Options
  • Bluetooth Modul
  • gas preparation unit
  • fresh air valve (dilution over all sensors factor 5)
  • single dilution with selectable factor
  • Special Gas pump
  • extern. DC power supply
  • automatic pressure zeroing
 
 
 
  • Thermocouple

    # 0430 0065

    NiCr-Ni, Inconel 625, 1.2 m long Meas. Range -200 to +1000 °C

  • Thermocouple

    # 0430 0066

    NiCr-Ni, Inconel 625, 2.2 m long Meas. Range -200 to +1000 °C

  • Connection hose, silicone, 5m long

    # 0554 0440

    (max. load 700 hPa (mbar))

  • Hose extension, 2.8 m

    # 0554 1202

    Еxtension cable for probe and analyser

  • Spare sintered filters (2 off)

    # 0554 3372
  • Spare particle filter (10 off) for probe handle

    # 0554 3385
  • Spare probe shaft with

    # 0554 7455
  • Probe shaft, 335 mm long

    # 0554 8764

    With probe stop, ∅ 8 mm, Tmax 1000 °C

  • Probe shaft, 700 mm long

    # 0554 8765

    With probe stop, ∅ 8 mm, Tmax 1000 °C

  • Probe shaft with preliminary filter

    # 0554 8767

    700 mm long, with probe stop, Ø 8 mm, Tmax 1000 °C

  • Probe shaft

    # 0554 9766

    335 mm long, with probe stop, Ø 8 mm, Tmax 500 °C

  • Probe shaft

    # 0554 9767

    700 mm long, with probe stop, Ø 8 mm, Tmax 500 °C

  • Flue gas probe for industrial engines

    # 0600 7555
    The flue gas probe from Testo can be used to carry out efficient and reliable flue gas measurements on stationary industrial engines. It can be used at flue gas temperatures of up to 1,000 °C
    Product benefits:
    • Made of metal: no melting of the handle due to radiated heat from the flue gas duct
    • Additional particle filter in the hose provides protection from contamination
    • Temperature measurement possible with optional thermocouple
    • Probe shaft is easy to replace
  • Flue gas probe with preliminary filter for industrial engines

    # 0600 7556

    Flue gas probe for industrial engines with probe shaft preliminary filter, 335 mm immersion depth incl. probe stop and heat protection plate, Tmax. +1,000 °C, special hose for NO2/SO2 measurements, length 4 m

  • Industrial probe

    # 0600 7610

    Industrial probe set 1200 °C consisting of: - unheated handle - unheated probe shaft up to 1200 °C flue gas temperature - unheated gas sampling hose incl. inline filter, length 4 m - thermocouple Type K, length 1.2 m

    Probe shaft: Tmax. +1200 °C, Length 1.0 m, Ø 12 mm
    Handle: Tmax. +600 °C
    Material: 1.4404 stainless steel
    Gas sampling hose: 2-chamber hose with PTFE inner core; length 4.0 m
    TC: Type K, Length 1.2 m, Ø 2 mm
    Tmax. +1200 °C
  • Thermocouple (2.2 m)

    # 0600 7615
    Type K
    lenght 2.2 m
    dia 2 mm
    T max 1200 C
  • Industrial probe preliminary filter

    # 0600 7616
    • Prevents the probe shaft and sampling hose from becoming clogged with dust
    • For measurements in dust-laden flue gas
    • Operating temperature up to 1000 °C
    • Diameter: 30 mm, length: 110 mm
  • Extension tube 1200 °C for extending the industrial probe set

    # 0600 7617

    Probe shaft: Tmax. +1200 °C Length 1.0 m, Ø 12 mm Material 2.4856 alloy 625

  • Industrial probe set 1 800 °C

    # 0600 7620
    - unheated handle
    - unheated probe shaft up to 1800 °C flue gas temperature
    - unheated gas sampling hose incl. inline filter, length 4 m
     
    Probe shaft: Tmax. +1800 °C
    Material Al2O3 > 99.7%
    Length 1.0 m, Ø 12 mm
    Gas sampling hose: 2-chamber hose with PTFE inner core; length 4.0 m
    Handle: Tmax. +600 °C
    Material: 1.4404 stainless steel
  • Flue gas probe, modular

    # 0600 8764

    335 mm immersion depth, incl. probe stop, thermocouple NiCr-Ni (TI) Tmax 1000°C and hose 2.2 m

  • Flue gas probe, modular

    # 0600 8765

    700 mm immersion depth, incl. probe stop, thermocouple NiCr-Ni Tmax 1000°C and hose 2.2 m

  • Flue gas probe, modular with preliminary filter

    # 0600 8766

    335 mm immersion depth, incl. probe stop, thermocouple NiCr-Ni (TI) Tmax 1000°C and hose 2.2 m

  • Flue gas probe, modular with preliminary filter

    # 0600 8767

    700 mm immersion depth, incl. probe stop, thermocouple NiCr-Ni (TI) Tmax 1000°C and hose 2.2 m

  • Thermocouple for exhaust gas temperature measurement

    # 0600 8894

    (NiCr-Ni, length 400 mm, Tmax. +1000 °C), with 2.4 m connection cable and additional temperature protection

  • Thermocouple for measuring exhaust gas temperature

    # 0600 8895

    (NiCr-Ni, length 400 mm, Tmax +1000 °C), with 5.2 m connection cable and additional temperature protection

  • Flue gas probe, modular

    # 0600 9766

    335 mm immersion depth, incl. probe stop, thermocouple NiCr-Ni (TI) Tmax 500°C and hose 2.2 m

  • Flue gas probe, modular

    # 0600 9767

    700 mm immersion depth, incl. probe stop, thermocouple NiCr-Ni (TI) Tmax 500°C and hose 2.2 m

  • Combustion air temperature probe

    # 0600 9797

    Immersion depth 60 mm Meas. Range 0 to +100 °C

  • Pitot tube

    # 0635 2041

    Stainless steel, 350 mm long, measures flow speed with temperature, 3 x hoses (5 m long) and heat protection plate Meas. Range -40 to +1000 °C

  • Pitot tube, 750 mm

    # 0635 2042

    Stainless steel, 750 mm long, measures flow speed with temperature, 3x hoses (5 m long) and heat protection plate Meas. Range -40 to +1000 °C

  • Pitot tube, 350 mm long, Ø 7 mm

    # 0635 2145

    Stainless steel, measures flow speed (In conjunction with 0638 1347 / 0638 1447 / 0638 1547 pressure probes or testo 521, with internal sensor)

  • Pitot tube, 1000 mm long

    # 0635 2345

    Stainless steel, measures flow speed (Longer versions on request)

  • Connection cable for Testo data bus

    # 0049 0076

    between Control Unit and analyzer box or between several analyzer boxes, with bayonet fitting, length 5 m

  • Connection cable for Testo databus

    # 0049 0077

    between Control Unit and analyzer box or between several analyzer boxes, with bayonet fitting, length 20 m

  • Option: CO (H2 compensated) measurement module, 0 to 10,000 ppm

    Option: CO (H2 compensated) measurement module, 0 to 10,000 ppm

    # 0393 1100
  • Option COlow (H2 compensated) measurement module, 0 to 500 ppm

    Option COlow (H2 compensated) measurement module, 0 to 500 ppm

    # 0393 1102
  • Option: NO measurement module, 0 to 3,000 ppm

    Option: NO measurement module, 0 to 3,000 ppm

    # 0393 1150
  • Option: NOlow measurement module, 0 to 300 ppm

    Option: NOlow measurement module, 0 to 300 ppm

    # 0393 1152
  • Option: NO2 measurement module, 0 to 500 ppm

    Option: NO2 measurement module, 0 to 500 ppm

    # 0393 1200
  • Option: SO2 measurement module, 0 to 5,000 ppm

    Option: SO2 measurement module, 0 to 5,000 ppm

    # 0393 1250
  • Extension cable

    # 0409 0063

    5 m long, between plug-in head cable and instrument (PUR coating material)

  • Connection cable for Testo databus

    # 0449 0075

    between Control Unit and analyzer box or between several analyzer boxes, with bayonet fitting, length 2 m

  • Transport case

    # 0516 3510

    For safe and tidy storage for flue gas analyzer testo 350, gas sampling probe and accessories, dimensions 570 x 470 210 mm (LxWxH) (Carrying strap set for analyzer box testo 350)

  • Transport case for probes

    # 0516 7600

    Suitable for all probeswith a total lenght >335 mm

  • Transport case for industrial probes, aluminium

    # 0516 7900

    (space for: handle, probes, flange and accessories)

  • Hose set to convey flue gas from analyzer box, 5 m long

    Hose set to convey flue gas from analyzer box, 5 m long

    # 0554 0451
    Meas. Range 0 to +500 ppm CO
  • Testo fast printer

    # 0554 0549

    With wireless infrared interface, 1 roll thermal paper and 4 AA batteries (for printing out measurements on site)

  • Spare thermal paper for printer (6 rolls

    # 0554 0568

    (measurement data documentation legible for up to 10 years)

  • Testo Bluetooth®/IRDA printer

    Testo Bluetooth®/IRDA printer

    # 0554 0620

     Incl. 1 roll of printer paper, rechargeable battery and mains unit

  • Cable with battery clamps

    Cable with battery clamps

    # 0554 1337
    and adapter for connection to testo 350-S/-XL
  • Analog ouput box set

    # 0554 3149

    6 channels, 4 to 20mA, for transfer of measurement values to e.g. analog recorder, set consists of analog output box, connection cable Testo databus, length 2 m, Testo databus input impedance.

  • "easyEmission" software for testo 340/350

    # 0554 3334

    With USB cable to connect instrument to PC

  • "easyEmission" software for testo 350

    # 0554 3336

    Testo data bus controller included, with USB to connect instrument to PC, cable for Testo data bus and terminal plug

  • Spare particle filter, pack of 20

    # 0554 3381
  • NO replacement filter, 1 off

    NO replacement filter, 1 off

    # 0554 4150
  • ISO calibration certificate/flue gas

    ISO calibration certificate/flue gas

    # 0520 0003
    (calibration points 2.5% O2; 100 and 1000 ppm CO; 800 ppm NO; 80 ppm NO2; 1000 ppm SO2)
  • ISO calibration certificate/Velocity

    ISO calibration certificate/Velocity

    # 0520 0034
    (hot wire, vane anemometer, Pitot tube; calibration points 5; 10; 15; 20 m/s)

 

Temperature - NTC                                             
Ambient temperature probe                  
Measuring range            
-20 to +50 °C
Accuracy
±0.2 °C (-10 to +50 °C)
Resolution
0.1 °C (-20 to +50 °C)                       
Temperature - TC Type K (NiCr-Ni)                      
                                                 
Measuring range
-200 to +1370 °C
Accuracy
±0.4 °C (-100 to +200 °C)                        
±1 °C (-200 to -100.1 °C)
±1 °C (200.1 to +1370 °C)
Resolution
0.1 °C (-200 to +1370 °C)
Temperature - TC Type S (Pt10Rh-Pt)                 
                                                              
Measuring range
0 to +1760 °C
Accuracy
±1 °C (0 to +1760 °C)
Resolution
0.1 °C (0 to +1760 °C)
Differential Pressure - Piezoresistive                   
                                                            
Measuring range
-40 to +40 hPa
-200 to +200 hPa
Accuracy
±1.5 % of mv (-40 to -3 hPa)
±1.5 % of mv (+3 to +40 hPa)
±0.03 hPa (-2.99 to +2.99 hPa)
±1.5 % of mv (-200 to -50 hPa)
±1.5 % of mv (+50 to +200 hPa)
±0.5 hPa (-49.9 to +49.9 hPa)
Resolution
0.01 hPa (-40 to +40 hPa)
0.1 hPa (-200 to +200 hPa)
Absolute Pressure                                               
                                                            
Measuring range
600 to +1150 hPa
Accuracy
±10 hPa
Resolution
1 hPa
opt. when equipped with IR sensor
Flue gas O₂                                                                                                                       
Measuring range
0 to +25 Vol.%
Accuracy
±0.8% of fsv (0 to +25 Vol.%)
Resolution
0.01 Vol.% (0 to +25 Vol.%)
Reaction time t₉₀
20 s (t95)
Flue gas CO (with H₂-compensation)                  
                                                              
Measuring range
0 to +10000 ppm
Accuracy
±5 % of mv (+200 to +2000 ppm)
±10 % of mv (+2001 to +10000 ppm)
±10 ppm (0 to +199 ppm)
Resolution
1 ppm (0 to +10000 ppm)
Reaction time t₉₀
40 s
H₂ only as an indicator
Flue gas COlow                                                  
                                                             
Measuring range
0 to 500 ppm                                           
Accuracy
±5 % of mv (+40 to +500 ppm)
±2 ppm (0 to +39.9 ppm)
Resolution
1 ppm (0 to +500 ppm)
Reaction time t₉₀
40 s
H₂ only as an indicator
Flue gas NO                                                        
                                                            
Measuring range
0 to +4000 ppm
Accuracy
±5 % of mv (+100 to +1999 ppm)
±10 % of mv (+2000 to +4000 ppm)          
±5 ppm (0 to +99 ppm)
Resolution
1 ppm (0 to +4000 ppm)
Reaction time t₉₀
30 s
Flue gas Nolow                                                   
                                                             
Measuring range
0 to +300 ppm
Accuracy
±5 % of mv (+40 to +300 ppm)                 
±2 ppm (0 to +39.9 ppm)
Resolution
±0.1 ppm (0 to +300 ppm)
Reaction time t₉₀
30 s
Flue gas NO₂                                                      
                                                              
Measuring range
0 to +500 ppm
Accuracy
±5 % of mv (+100 to +500 ppm)
±5 ppm (0 to +9.99 ppm)
Resolution
0.1 ppm (0 to +500 ppm)
Reaction time t₉₀
40 s
Flue gas SO₂                                                       
                                                             
Measuring range
0 to +5000 ppm
Accuracy
±5 % of mv (+100 to +2000 ppm)
±10 % of mv (+2001 to +5000 ppm)
±5 ppm (0 to +99 ppm)
Resolution
1 ppm (0 to +5000 ppm)
Reaction time t₉₀
30 s
Flue gas degree of effectivity, Eta (calculated)      
                                                            

Measuring range

0 to +120 %
Resolution
0.1 % (0 to +120 %)
Flue gas loss (calculated)                                    
                                                             
Measuring range
0 to +99.9 %
Resolution
0.1 % (0 to +99.9 %)
Flue gas dewpoint (calculated)                            
                                                             
Measuring range
0 to +99.9 °Ctd
Resolution
0.1 °Ctd (0 to +99.9 °Ctd)
Flue gas CO₂ calculation (calculated from O₂)     
                                                             
Measuring range
0 to CO₂ max
Accuracy
calculated from O₂ ±0.2 Vol.%
Resolution
0.01 Vol.%
Flue gas H₂S                                                       
                                                             
Measuring range
0 to +300 ppm
Accuracy
±5 % of mv (+40 to +300 ppm)
±2 ppm (0 to +39.9 ppm)
Resolution
0.1 ppm (0 to +300 ppm)
Reaction time t₉₀
35 s
 
Flue gas CO₂ - NDIR                                          
Measuring range
0 to +50 Vol.%
Accuracy
±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%)
±0.5 Vol.% + 1.5 % of mv (25 to 50 Vol.%)
Resolution
0.01 Vol.% (0 to 25 Vol.%)
0.1 Vol.% (> 25 Vol.%)
Reaction time t₉₀
10 s
Velocity / Volume flow                                      
                                                              
Measuring range
0 to +40 m/s
Resolution
0.1 m/s (0 to +40 m/s)
Methane (CH₄)                                                   
                                                              
Measuring range
100 to 40000 ppm
Accuracy
< 400 ppm (100 to 4000 ppm)
< 10 % of mv (> 4000 ppm)
Resolution
10 ppm
Min. O₂ requirement in flue gas
2 % + (2 x mV methane)
Reaction time t₉₀
< 40 s
Response factor
1
Lower explosion limit (LEL) must be adhered to. 
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Propane (C₃H₈)                                                 
                                                              
Measuring range
100 to 21000 ppm
Accuracy
< 400 ppm (100 to 4000 ppm)
< 10 % of mv (> 4000 ppm)
Resolution
10 ppm
Min. O₂ requirement in flue gas
2 % + (5 x mV propane)
Reaction time t₉₀
< 40 s
Response factor
1.5
Lower explosion limit (LEL) must be adhered to. 
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Butane (C₄H₁₀)                                                 
                                                              
Measuring range
100 to 18000 ppm
Accuracy
< 400 ppm (100 to 4000 ppm)
< 10 % of mv (> 4000 ppm)
Resolution
10 ppm
Min. O₂ requirement in flue gas
2 % + (6.5 x mV butane)
Reaction time t₉₀
< 40 s
Response factor
2
Lower explosion limit (LEL) must be adhered to. 
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
 

General technical data                                                                                        

Housing
ABS
Protection class
IP40
Warranty
Measuring instrument 2 years (excepting wearing parts e.g. gas sensors);
CO, NO2, SO₂, H₂S, CxHy, NOlow sensor, NO, COlow: 12 months;
CO₂-IR sensors: 24 months; Sensor O₂: 18 months;
rechargeable battery: 12 months;
Battery type
lithium batteries
Battery life
5 h
Power supply
AC mains unit 100V to 240V (50 to 60 Hz)
DC electric tension input
11V to 40V
Pump flow
1 l/min. with through-flow monitoring
Hose length
16.2 m (corresponds to 5 probe hose extensions)
Max. pos. press./flue gas
50 mbar
Max. neg. press./flue gas
-300 mbar
Max. dust load
20 g/m³ dust in flue gas
Dewpoint calculation
0 °Ctd; 99 °Ctd
Max. humidity load
70 °C dewpoint temperature
Trigger input
Voltage 5 to 12 Volt (rising or trailing edge) pulse width > 1 sec load: 5 V/max, 5 mA, 12 V/max. 40 mA
Maximum
250,000 readings

 

 

 

 

Enquiry Form

Related products

  • testo 350-MARITIME

    testo 350-MARITIME

    Portable exhaust gas analyzer - for exhaust gas analysis on marine diesel engines.
  • testo 340

    testo 340

    testo 340 flue gas analyzer incl. rechargeable battery, instruction manual and carry strap, equipped with O2 sensor and built-in flow/differential...
  • testo 350 Control-Unit

    testo 350 Control-Unit

    testo 350 Control Unit, displays measurement values and controls analyzer box, incl. rech. battery, measurement data store, USB interface and...