testo 340 flue gas analyzer incl. rechargeable battery, instruction manual and carry strap, equipped with O2 sensor and built-in flow/differential pressure measurement
 
Part #: 0632 3340

Description

Rising fuel costs for thermal systems highlight more and more the need for efficiency monitoring using emission measurements. A practical, easy-to-use emission analyzer for a variety of applications is therefore ideal. testo 340 is equipped with an O2 sensor as standard. 3 additional gas sensors can be individually configured at any time so your analyzer is optimally adpated to your measurement job. Compact design combined with reliable engineering makes testo 340 the ideal analyzer for commissioning, service and maintenance work as well as measurements for monitoring purposes. • Industrial burners • Stationary industrial engines • Gas turbines • Thermal processes

  • precalibrated „plug & play“ sensors
  • 3 sensors freely selectable (O2 standard, a second sensor must be fitted) CO, COlow, NO, NOlow, NO2 und SO2
  • pressure-/ flow-measurement standard in every testo 340
  • measurement range extension for Single dilution slot or optional for all sensors
  • automatic flow-controlled gas pump
  • modular gas sampling probes
  • internal data logging
  • option: Data transfer and real-time-analyzer-control via Bluetooth® module and software easyEmission
  • 18 standard fuels and additional 10 user-defined fuels – Fuel data is calculated using software easyEmission
testo 340 must be equipped with a second gas sensor otherwise the analyzer cannot function. Max. 3 additional sensors can be fitted.
 
 
  • Thermocouple

    # 0430 0065

    NiCr-Ni, Inconel 625, 1.2 m long Meas. Range -200 to +1000 °C

  • Thermocouple

    # 0430 0066

    NiCr-Ni, Inconel 625, 2.2 m long Meas. Range -200 to +1000 °C

  • Hose extension, 2.8 m

    # 0554 1202

    Еxtension cable for probe and analyser

  • Spare particle filter (10 off)

    # 0554 3371

    For condensate trap in gas sampling hose

  • Spare sintered filters (2 off)

    # 0554 3372
  • Spare particle filter (10 off) for probe handle

    # 0554 3385
  • Probe shaft, 335 mm long

    # 0554 8764

    With probe stop, ∅ 8 mm, Tmax 1000 °C

  • Probe shaft, 700 mm long

    # 0554 8765

    With probe stop, ∅ 8 mm, Tmax 1000 °C

  • Probe shaft with preliminary filter

    # 0554 8766

    335 mm long, with probe stop, Ø 8 mm, Tmax 1000 °C

  • Probe shaft with preliminary filter

    # 0554 8767

    700 mm long, with probe stop, Ø 8 mm, Tmax 1000 °C

  • Probe shaft

    # 0554 9767

    700 mm long, with probe stop, Ø 8 mm, Tmax 500 °C

  • Mini ambient air probe

    # 0600 3692

    Tmax +80°C, for separate ambient air temperature measurement Meas. Range 0 to +80 °C

  • Pipe wrap probe Type K (NiCr-Ni)

    # 0600 4593

    For pipes with diameter of up to 2", for flow/return temp. meas. in hydronic systems Meas. Range -60 to +130 °C

  • Flue gas probe for industrial motors

    # 0600 7560

    335 mm immersion depth, with probe stop, built-in condensate trap and heat protection plate, Tmax 1000 °C, special hose for NO2/SO2 measurements, 2.2 m long

  • Flue gas probe for industrial motors with probe shaft prefilter

    # 0600 7561

    335 mm immersion depth, with probe stop, built-in condensate trap and heat protection plate, Tmax 1000 °C, special hose for NO2/SO2 measurements, 2.2 m long

  • Industrial probe

    # 0600 7610

    Industrial probe set 1200 °C consisting of: - unheated handle - unheated probe shaft up to 1200 °C flue gas temperature - unheated gas sampling hose incl. inline filter, length 4 m - thermocouple Type K, length 1.2 m

    Probe shaft: Tmax. +1200 °C, Length 1.0 m, Ø 12 mm
    Handle: Tmax. +600 °C
    Material: 1.4404 stainless steel
    Gas sampling hose: 2-chamber hose with PTFE inner core; length 4.0 m
    TC: Type K, Length 1.2 m, Ø 2 mm
    Tmax. +1200 °C
  • Thermocouple (2.2 m)

    # 0600 7615
    Type K
    lenght 2.2 m
    dia 2 mm
    T max 1200 C
  • Industrial probe preliminary filter

    # 0600 7616
    • Prevents the probe shaft and sampling hose from becoming clogged with dust
    • For measurements in dust-laden flue gas
    • Operating temperature up to 1000 °C
    • Diameter: 30 mm, length: 110 mm
  • Extension tube 1200 °C for extending the industrial probe set

    # 0600 7617

    Probe shaft: Tmax. +1200 °C Length 1.0 m, Ø 12 mm Material 2.4856 alloy 625

  • Industrial probe set 1 800 °C

    # 0600 7620
    - unheated handle
    - unheated probe shaft up to 1800 °C flue gas temperature
    - unheated gas sampling hose incl. inline filter, length 4 m
     
    Probe shaft: Tmax. +1800 °C
    Material Al2O3 > 99.7%
    Length 1.0 m, Ø 12 mm
    Gas sampling hose: 2-chamber hose with PTFE inner core; length 4.0 m
    Handle: Tmax. +600 °C
    Material: 1.4404 stainless steel
  • Heated industrial probe set

    # 0600 7630
    - heated probe shaft up to 600 °C flue gas temperature
    - heated gas sampling hose, length 4 m
    - thermocouple Type K, length 1.2 m
     
    Probe shaft: temperature-proof up to +600 °C
    Voltage supply: 230 V / 50 Hz
    Length: 1.0 m, Ø 25 mm
    Heating temperature range: +200 °C
    Material: stainless steel 1.4571
    Gas sampling hose: corrugated hose with PTFE inner core, Length 4.0 m; outside diameter 34 mm
    Heating temperature range > +120 °C TC:
    Type K - Length 1.2 m, Ø 2 mm Tmax. +1200 °C

     

  • Flue gas probe, modular

    # 0600 8764

    335 mm immersion depth, incl. probe stop, thermocouple NiCr-Ni (TI) Tmax 1000°C and hose 2.2 m

  • Flue gas probe, modular

    # 0600 8765

    700 mm immersion depth, incl. probe stop, thermocouple NiCr-Ni Tmax 1000°C and hose 2.2 m

  • Flue gas probe, modular with preliminary filter

    # 0600 8766

    335 mm immersion depth, incl. probe stop, thermocouple NiCr-Ni (TI) Tmax 1000°C and hose 2.2 m

  • Flue gas probe, modular with preliminary filter

    # 0600 8767

    700 mm immersion depth, incl. probe stop, thermocouple NiCr-Ni (TI) Tmax 1000°C and hose 2.2 m

  • Thermocouple for exhaust gas temperature measurement

    # 0600 8894

    (NiCr-Ni, length 400 mm, Tmax. +1000 °C), with 2.4 m connection cable and additional temperature protection

  • Flue gas probe, modular

    # 0600 9766

    335 mm immersion depth, incl. probe stop, thermocouple NiCr-Ni (TI) Tmax 500°C and hose 2.2 m

  • Flue gas probe, modular

    # 0600 9767

    700 mm immersion depth, incl. probe stop, thermocouple NiCr-Ni (TI) Tmax 500°C and hose 2.2 m

  • Combustion air temperature probe

    # 0600 9797

    Immersion depth 60 mm Meas. Range 0 to +100 °C

  • Pitot tube

    # 0635 2041

    Stainless steel, 350 mm long, measures flow speed with temperature, 3 x hoses (5 m long) and heat protection plate Meas. Range -40 to +1000 °C

  • Pitot tube, 750 mm

    # 0635 2042

    Stainless steel, 750 mm long, measures flow speed with temperature, 3x hoses (5 m long) and heat protection plate Meas. Range -40 to +1000 °C

  • Pitot tube, 350 mm long, Ø 7 mm

    # 0635 2145

    Stainless steel, measures flow speed (In conjunction with 0638 1347 / 0638 1447 / 0638 1547 pressure probes or testo 521, with internal sensor)

  • Pitot tube, 1000 mm long

    # 0635 2345

    Stainless steel, measures flow speed (Longer versions on request)

  • Option: CO (H2 compensated) measurement module, 0 to 10,000 ppm

    Option: CO (H2 compensated) measurement module, 0 to 10,000 ppm

    # 0393 1100
  • Option COlow (H2 compensated) measurement module, 0 to 500 ppm

    Option COlow (H2 compensated) measurement module, 0 to 500 ppm

    # 0393 1102
  • Option: NO measurement module, 0 to 3,000 ppm

    Option: NO measurement module, 0 to 3,000 ppm

    # 0393 1150
  • Option: NOlow measurement module, 0 to 300 ppm

    Option: NOlow measurement module, 0 to 300 ppm

    # 0393 1152
  • Option: NO2 measurement module, 0 to 500 ppm

    Option: NO2 measurement module, 0 to 500 ppm

    # 0393 1200
  • Option: SO2 measurement module, 0 to 5,000 ppm

    Option: SO2 measurement module, 0 to 5,000 ppm

    # 0393 1250
  • Extension cable

    # 0409 0063

    5 m long, between plug-in head cable and instrument (PUR coating material)

  • Option: BLUETOOTH® module

    Option: BLUETOOTH® module

    # BLUETOOTH
  • Option: dilution of all sensors

    Option: dilution of all sensors

    # DILUTION
  • Transport case for analyzer and probes

    Transport case for analyzer and probes

    # 0516 3340
  • Transport case for probes

    # 0516 7600

    Suitable for all probeswith a total lenght >335 mm

  • Connection hose, silicone, 5m long

    # 0554 0440

    (max. load 700 hPa (mbar))

  • Testo fast printer

    # 0554 0549

    With wireless infrared interface, 1 roll thermal paper and 4 AA batteries (for printing out measurements on site)

  • BLUETOOTH® printer

    # 0554 0553

    Set with wireless Bluetooth interface, incl. 1 roll thermal paper, rechargeable battery and mains unit

  • Spare thermal paper for printer (6 rolls

    # 0554 0568

    (measurement data documentation legible for up to 10 years)

  • 100-240 V DC mains unit

    # 0554 1096

    (for testo Saveris base, router, converter, Ethernet probe)

  • Charger for spare battery

    # 0554 1103
  • Instrument cleaner (100 ml)

    Instrument cleaner (100 ml)

    # 0554 1207
    (for hassle-free and fast removal of dirt from housing, display screen, keypad, probe handle and probe cable)
  • "easyEmission" software for testo 340/350

    # 0554 3334

    With USB cable to connect instrument to PC

  • "easyEmission" software

    # 0554 3338
  • CO replacement filter, 1 off

    CO replacement filter, 1 off

    # 0554 4100
  • NO replacement filter, 1 off

    NO replacement filter, 1 off

    # 0554 4150
  • ISO calibration certificate/flue gas

    ISO calibration certificate/flue gas

    # 0520 0003
    (calibration points 2.5% O2; 100 and 1000 ppm CO; 800 ppm NO; 80 ppm NO2; 1000 ppm SO2)
  • ISO calibration certificate velocity

    ISO calibration certificate velocity

    # 0520 0004
    (hot wire, vane anemometer, Pitot tube; calibration points 1; 2; 5; 10 m/s)
  • ISO calibration certificate/Velocity

    ISO calibration certificate/Velocity

    # 0520 0034
    (hot wire, vane anemometer, Pitot tube; calibration points 5; 10; 15; 20 m/s)
  • ISO calibration certificate temperature

    # V400 0000
Differential Pressure
Measuring range                                                  
-200 to 200 hPa                                           
Accuracy
±0.5 hPa (-49.9 to 49.9 hPa)
±1.5 % of mv (Remaining Range)
Resolution
0.1 hPa
 
Absolute Pressure
Measuring range                                                 
+240 to +460 InH₂O / +600 to +1150 hPa    
Accuracy
±4 InH₂O / ±10 hPa
Resolution
0 InH₂O / 1 hPa
 
Flue gas O₂

 Measuring range                                                

0 to 25 Vol.%                                                 
Accuracy
±0.2 Vol.%
Resolution
0.01 Vol.%
Reaction time t₉₀
< 20 sec
 
Flue gas CO (with H₂-compensation)
Measuring range                                                 
0 to 10000 ppm                                              
Accuracy
±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 10000 ppm)
Resolution
1 ppm
Reaction time t₉₀
< 40 sec
 
Flue gas COlow
Measuring range                                              
0 to 500 ppm
Accuracy
±2 ppm (0 to 39.9 ppm)
±5 % of remaining measurement value
(Remaining Range) data corresponds to
20°C ambient temperature. Additional temperature
coefficient 0.25% of reading/K.
Resolution
0.1 ppm
Reaction time t₉₀
< 40 sec
 
Flue Gas NO
Measuring range                              
0 to 4000 ppm
Accuracy
±5 ppm (0 to 99 ppm)
±5 % of remaining measurement value (100 to 1999 ppm)
±10 % of remaining measurement value (2000 to 4000 ppm)
Resolution
1 ppm
Reaction time t₉₀
< 30 sec
 
Flue Gas No low
Measuring range                              
0 to 300 ppm                                                                          
Accuracy
±2 ppm (0 to 39.9 ppm)
±5 % of remaining measurement value (Remaining Range)
Resolution
0.1 ppm
Reaction time t₉₀
< 30 sec
 
Flue Gas NO₂
Measuring range                                
0 to 500 ppm
Accuracy
±10 ppm (0 to 199 ppm)
±5 % of remaining measurement value (Remaining Range)
Resolution
0.1 ppm
Reaction time t₉₀
< 40 sec
To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.
 
Flue Gas SO₂
Measuring range                               
0 to 5000 ppm
Accuracy
±10 ppm (0 to 99 ppm)
±10 % of remaining measurement value (Remaining Range)
Resolution
1 ppm
Reaction time t₉₀
< 40 sec
To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.
 
Flue Gas Draft
Measuring range                     
-16 to +16 InH₂O / -40 to +40 hPa
Accuracy
±0.01 InH₂O (-1.20 to +1.20 InH₂O) / ±0.03 hPa (-2.99 to +2.99 hPa)
±1.5 % of remaining measurement value (Remaining Range)
Resolution
0.00 InH₂O / 0.01 hPa
 
Temperature
Measuring range                     
-40.0° to 2192.0 °F / -40 to +1200 °C                                                 
Accuracy
±0.9 °F (32.0° to 210.2 °F) / ±0.5 °C (0 to +99 °C)
±0.5 % of remaining measurement value (Remaining Range)
Resolution
0.1 °F / 0.1 °C
 
Efficiency (calculated)
Measuring range                    
0 to 120 %                                                                                          
Resolution
0.1 %
 
Flue Gas loss (calculated)
Measuring range                    
0 to 99.9 %                                                                                        
Resolution
0.1 %
 
Flue Gas dewpoint (calculated)
Measuring range                    
0.0° to 99.9 °Ctd                                                                              
Resolution
0.1 °Ctd
 
Flue Gas CO₂ calculation (calculated from O₂)
Measuring range                   
0 to CO₂ max                                                                                   
Accuracy
±0.2 Vol.%
Resolution
0.1 Vol.%
Reaction time t₉₀
< 40 sec
 
General technical data
Housing
TPE PC
Protection class
IP40
Warranty
Measuring instrument 2 years (excepting wearing parts e.g. gas sensors, etc.);
rechargeable battery: 12 months; CO sensor: 12 months; Sensor NOlow: 12 months;
Sensor NO2: 12 months; Sensor SO₂: 12 months; Sensor O₂: 18 months;
NO sensor 12 months; COlow sensor 12 months
Display size
160 x 240 pixels
Display function
Graphic display
Power supply
Battery block 3.7 V / 2.4 Ah, Mains unit 6.3 V / 2 A
User defined fuels
10 user-defined fuels incl. test gas as fuel
Pump flow
0.6 l/min (regulated)
Hose length
max. 7.8 m (corresponds to two probe hose extensions)
Max. pos. press./flue gas
50 mbar
Max. neg. press./flue gas
-200 mbar
Maximum
100 folders
Storage per folder
Max. 10 sites
Storage per site
Max. 200 logs
Miscellaneous
The max. number of logs is determined by the number of folders or sites
 

Enquiry Form

Related products

  • testo 350 Analyzer box

    testo 350 Analyzer box

    testo 350 Analysis Box, O2, incl. differential pressure sensor, type K NiCr-Ni and type S temperature sensor port, Pt10Rh-Pt, Testo...
  • testo 350 Control-Unit

    testo 350 Control-Unit

    testo 350 Control Unit, displays measurement values and controls analyzer box, incl. rech. battery, measurement data store, USB interface and...
  • testo 350-MARITIME

    testo 350-MARITIME

    Portable exhaust gas analyzer - for exhaust gas analysis on marine diesel engines.